• SIGN PROCESS
    • Assessment
    • Wayfinding
    • Design & Planning
    • Sign Selection
      • Interior Signage
      • Exterior Signage
      • Digital Signage
    • Project Management
    • Implementation
    • Maintenance
  • PRODUCTS
  • SOLUTIONS
    • ADA Compliant
    • Corporate
    • Cultural
    • Donor Recognition
    • Education
    • Government
    • Healthcare
    • International
    • Sustainable
  • SUCCESS STORIES
  • LOCATIONS
  • NEWS
  • ABOUT
ASI SignageASI Signage
  • SIGN PROCESS
    • Assessment
    • Wayfinding
    • Design & Planning
    • Sign Selection
      • Interior Signage
      • Exterior Signage
      • Digital Signage
    • Project Management
    • Implementation
    • Maintenance
  • PRODUCTS
    • Interior SignageExterior SignageDigital Signage

      ADA-Ready™ Signage Options

      • InForm™
      • InTouch™
      • InTac™
      • InTac Eco™
      • Terra
      • SignEtch™

      Modular Signage Systems

      • Puzzle™
      • Jigsaw™
      • PerFORM™
      • Infinity™
      • Pacific Interior™
      • Messenger Interior™

      Extrusion Signage Systems

      • Horizon
      • Venus
      • Fascia

      Additional Interior Signage

      • Dimensional Letters
      • Custom Signage

      Modular Signage Systems

      • Messenger Exterior™
      • Pacific Exterior™
      • Compass™

      Additional Exterior Signage

      • Dimensional Letters
      • Custom Signage

      Interior Digital Signage

      • Digital Signage
      • SlimLine
      • ID Screen

      Exterior Digital Signage

      • LED Digital Signage
  • SOLUTIONS
    • ADA Compliant
    • Corporate
    • Cultural
    • Donor Recognition
    • Education
    • Government
    • Healthcare
    • International
    • Sustainable
  • SUCCESS STORIES
  • LOCATIONS
  • NEWS
  • ABOUT

5 Challenges that Arise During an ADA Retrofit

Home ada signage5 Challenges that Arise During an ADA Retrofit

5 Challenges that Arise During an ADA Retrofit

May 31, 2016 Posted by Liz Kelly

5 Challenges that Arise During an ADA Retrofit

For those contemplating a remodel of their office, one of the most important aspects of the project is ensuring compliance with the Americans with Disabilities Act (ADA). The most recent comprehensive ADA Standards for Accessible Design were issued in 2010. Today, if a client is renovating an older facility, or even an office remodeled six years ago, they may think they are compliant by still referring to the regulations that were current when their offices were built. The reality is that they’d be non-compliant, and that could cost a significant amount of time and money.

Here are the top five points to keep in mind when retrofitting and remodeling:

1) Lunchrooms: Counters cannot exceed 34 inches in height at the sink area and must have a 30 inch wide clearance below for a wheelchair to roll under the sink. The challenge here is finding smaller, compatible appliances, like dishwashers and under-counter refrigerators. While more manufacturers are becoming ADA height conscious, at times sinks and the rest of the counters are installed at two different heights. The microwave must also be offered at ADA accessible height and not be placed in an upper cabinet.

2) Restrooms: Restrooms are one area where several new standards have been added. All toilets must meet ADA unless the restroom is accessed only through a private office, is not for common or public use and is intended for use by a single occupant. A few alternatives are allowed in this case but the restroom must be able to meet ADA standards when the alternatives are removed. Current code requires additional unencumbered areas. The toilet must be placed in a clear space 56/59 inches front to back and 60 inches clear space from sidewall to sink edge. The sink must have a 30 inch side to side and 48 inch front to back clear area and the same size clear area must be offered between the sink and the toilet. Numerous other revised requirements for accessory and grab bar placement are listed in the standards.

3) Door Clearances: There are two important factors about doors. All doors must provide a clear width of 32 inches and must provide maneuvering clearances for those in wheelchairs. There are several standards for maneuvering clearances but the most basic for a front approach is 18 inches clear space at the pull side of the door and 12 inches clear space at the push side of the door. The ADA standards cover all types of doors, including hinged, revolving, sliding, manual and automatic.

4) Built-in Reception Counters:  A typical reception counter is 42 inches high. But with ADA regulations, an area no more than 34 inches high and no less than 36 inches wide must be provided. From a design standpoint, the 34 inch walk up counter height means much more of the receptionist’s worksurface contents are in full view, which usually is undesirable from a privacy and aesthetic point. One way to alleviate this is to offer both the shorter counter for wheelchair users and a higher counter for able-bodied individuals.

5) Signage: Not all signs are required to be both visual and tactile with braille. Some exemptions include building directories, addresses, company names and logos. ADA standards list character spacing, style and size requirements. A range of 48 inches minimum and 60 inches maximum is now the standard height to the baseline for tactile signage.

While these are just the highlights for some of the most common components of a facility, there are many more requirements that need to be met. In addition to individuals in wheelchairs, other disabilities have to be taken into consideration such as those hard of hearing or blind. Before you start, consult your architect or interior designer. It is a much more prudent – and cost effective – approach to be proactive in design than reactive.

 

For more information:

http://www.buildings.com/buzz/buildings-buzz/entryid/341/5-challenges-that-arise-during-an-ada-retrofit.aspx

0
Share

You also might be interested in

Wayfinding, ADA Signs, and 3form Posts Leap Ahead in 2012

Feb 29, 2012

Dear “Conversations About Signage” Readers, As you know from every[...]

Applying Clarity to ADA Signage Contrast Requirements

Jun 30, 2011

“I thought the  ADA mandates a minimum 70% contrast level[...]

Sign Judgments: Huge Exterior Digital Signage for Wilshire Grand Hotel Causes Controversy

Apr 15, 2011

California has long been known as being on the cutting[...]

Latest News

ASI’s Skilled Project Managers

ASI’s Skilled Project Managers

August 28, 2020

After meeting with an ASI Sales Consultant to customize the...

Safe Workplace Signage Flipbook

Safe Workplace Signage Flipbook

June 25, 2020

ASI’s Healthcare Impact

ASI’s Healthcare Impact

April 22, 2020

ASI has been providing signage services and solutions to...

Sign On – ASI is Open

Sign On – ASI is Open

March 19, 2020

Sometimes the smallest signs are the most important, like...

May 2016
M T W T F S S
 1
2345678
9101112131415
16171819202122
23242526272829
3031  
« Apr   Jun »

Archives

  • August 2020
  • June 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • July 2019
  • April 2019
  • February 2019
  • January 2019
  • December 2018
  • November 2018
  • September 2018
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • March 2018
  • February 2018
  • January 2018
  • December 2017
  • November 2017
  • October 2017
  • September 2017
  • August 2017
  • July 2017
  • June 2017
  • May 2017
  • March 2017
  • February 2017
  • January 2017
  • December 2016
  • November 2016
  • October 2016
  • August 2016
  • July 2016
  • June 2016
  • May 2016
  • April 2016
  • March 2016
  • February 2016
  • January 2016
  • October 2015
  • September 2015
  • July 2015
  • June 2015
  • November 2014
  • October 2014
  • September 2014
  • August 2014
  • July 2014
  • June 2014
  • May 2014
  • April 2014
  • March 2014
  • February 2014
  • January 2014
  • November 2013
  • September 2013
  • August 2013
  • July 2013
  • May 2013
  • April 2013
  • March 2013
  • February 2013
  • January 2013
  • December 2012
  • November 2012
  • October 2012
  • September 2012
  • August 2012
  • July 2012
  • June 2012
  • May 2012
  • April 2012
  • March 2012
  • February 2012
  • January 2012
  • December 2011
  • November 2011
  • October 2011
  • September 2011
  • August 2011
  • July 2011
  • June 2011
  • May 2011
  • April 2011
  • March 2011
  • February 2011
  • January 2011
  • December 2010

Contact

Point of Contact:
Steve Calhoun
Email
Tel 314.421.2288

Request a consultation for your architectural signage solution today! Get Started

Company Information

  • ASI SIGN SYSTEMS, INC.
  • Corporate Office:
    8181 Jetstar Drive, Suite 100,
    Irving TX 75063
  • 1.800.274.7732

Contact & Support

  • Contact Us
  • Client Portals
  • Careers
  • Register for Updates

Resources

  • Colors & Finishes
  • LRV Calculator
  • Continuing Education
  • Resource Documents

Privacy Statement • Legal
© Copyright 2022 . ASI Sign Systems, Inc. dba ASI. All rights Reserved.

Prev Next
Cookie Consent Options